Integral X-LINE. The Integral X-LINE permits loop lengths of up to 3,500m with up to 250 devices per loop. Short start-up times for loopsmake the commissioning process simple and quick even when the maximum number of devices are connected.
Multiple sensor detector MTD 533X. Combined scattered light smoke detector and temperature detector for early detection of smouldering or open fires with or without smoke formation.
Manual call point MCP 535X. Type B manual call point pursuant to EN 54-11 for manual triggering of a fire alarm, suitable for connection to the Integral X-LINE.
Manual call point MCP 545X. Type A manual call point pursuant to EN 54-11 for manual triggering of a fire alarm, suitable for connection to the Integral X-LINE.
Ventilation duct detector LKM 531. For use in places where there is a high airspeed and strong smoke dispersal e.g. air conditioning and ventilation ducts.
BX-SOL loop siren. BX-SOL loop siren for acoustic signalling of a fire alarm in interior spaces. The type of tone is set from the fire alarm control panel, with the volume being set using DIP switches.
BX-FOL flashing light. BX-FOL flashing light for optical signalling of a fire alarm in interior spaces. The flash rate and the light intensity are set using DIP switches.
BX-SBL501 based-mounted siren. BX-SBL501 based-mounted siren for acoustic signalling of a fire alarm in an interior area (type A pursuant to EN 54-3) is fitted as a unit with a USB 501 detector base.
BX-SBL502 platform siren. BX-SBL502 platform siren for acoustic signalling of a fire alarm in interior spaces. (Type A pursuant to EN 54-3).
BX-OI3 input/output module. BX-OI3 input/output module with relay output with a programmable fail-safe position, two inputs for querying potential-free contacts and an optocoupler input for monitoring external voltages.
BX-IOM input/output module. BX-IOM input/output module with short circuit resistant monitored output and galvanically isolated input for controlling monitored devices, which are supplied with power by an external power supply (e.g. sirens etc.).
BX-IM4 input module. BX-IM4 input module with 4 inputs for monitored and non-monitored querying of potential-free contacts, suitable for handling switching times of more than 330 ms.
BX-REL4 relay module. BX-REL4 relay module contains 4 bistable relays each with a potential-free double-throw contact with a fail-safe position.
BX-AIM input module. BX-AIM input module with monitored input and parallel indicator output is used to connect threshold detectors to the Integral X-LINE or as a branch unit for monitoring hazardous areas.
BX-ESL end position switch. BX-ESL end position switch for deployment in sprinkler monitoring and for blocking systems. The module contains an optical light barrier which measures the movement of an activation plunger.